Model H-418C
- 1250 Watts of Power
- VERSATILE DESIGN – Easily converts between floating and submergible de-icer
- Constructed of Cast Aluminum for ultimate efficiency and safety
- Thermostatically controlled to operate only when necessary
- Heavy duty “anti-chew” cord protector
- SAFE IN PLASTIC
- Guaranteed for Three Years
Download De-Icer Instructions
Download About Your De-Icer & Trouble Shooting Guide
Product Video
Product Buying Guide
Use this guide to determine the appropriate de-icer. Different de-icers should be depending on your application, geographical location, and volume of water. Note, some de-icers are safe in plastic and others are not. Please reach out to Farm Innovators customer service team if you have specific questions about which de-icer to use for your specific needs.
Get Support Information
Find a Dealer

Frequently Asked Questions
The H-418/P-418 Floating De-icer is 10% buoyant, enough to keep them afloat. If they sink it’s most likely due to added weight on the unit or cord, cast housing, etc. This can occur with lime build up. We recommend cleaning your de-icer every 30 days to prevent lime and mineral build up.
Due to the warm ambient temperature in the retail store, the thermostat has not been in cold temperature long enough to re-set the thermostat to the “on” position. (On at 35F, Off at 45F).
All of our tank deicers are thermostatically controlled. The unit will turn on
when the water temperature around the heating element is at 35° F and will
normally turn off when the water temperature in the specific application is at
45° F (at -10° F outside temperature.) If the air temperature is greater than
-10° F, then the water temperature may be a little warmer than 45° F before
shutting off.
You can use white vinegar and water, Lime-Away or CLR to clean the
element. We recommend periodic cleaning during the winter months for
maximum performance and efficiency.
It is a calcium buildup that needs to be cleaned so the unit performs at
manufacture’s specifications. This sometimes occurs in areas like the
Northeast that has “hard” water or other impurities in the water. Allowing the
calcium buildup or other impurities to cover the entire heating element
without cleaning it off may cause the heating element to burn out due to not
being able to disperse heat.
Connecting the unit to an extension cord over a long distance will result in
fewer volts and less power. For example, if the voltage drops from 120 VAC
to 105VAC while the amps remain the same, the wattage (power) will
automatically drop. (Ex. 105VAC x 8.5A = 892.5 watts compared to 120VAC x
8.5A = 1020 watts.) If an extension cord is used, it should be a heavy gauge
3 conductor, designed for outdoor use only, and as short as possible.
Numerous factors may be involved in making your unit not work efficiently.
These include the placement of de-icer (wind factor), outside ambient
temperature far below zero (sub-zero conditions), high wind chill factor,
volume of water, wrong de-icer (wattage) purchased for the particular
application, and the use of a long extension cords (reduces wattage).
Completing the “Air Test” will eliminate your concern.
We recommend grounding your tank or pond for the “ultimate” safety
application when using any de-icer. You can purchase a grounding kit at your
local hardware or easily make one yourself {parts needed: one 8’ foot metal
ground rod, two (2) metal clamps and a spool of “uninsulated” copper wire}.
Drive the 8’ long metal rod nearly all the way into the ground next to the tank
or pond. Next, clamp the uninsulated copper wire to the side of a metal tank
or drape the copper wire into the bottom of a plastic tank. Finally, connect
the other end of the uninsulated copper wire to the metal post.
Our metal parts are dipped into a protective pre-coating material to
help reduce the possibility of corrosion and/or rust. Nevertheless, rust may
occur in areas like the Northeast where the impurities in the water can break
down the protective coating. Roughing up the corrosion and spray painting
the metal parts with rustoleum paint should stop further damage.
The cast aluminum units, like all of our units, have a thermostat which is set
to turn on when the water temperature approaches freezing (35° F). The unit
is set to turn off when the de-icer reaches its “internal temperature”, which at
-10° F will make the water temperature in the correct application be 42° –
47° F. If the air temperature is significantly above our testing model (-10°F)
then the water temperature may be slightly warmer than our above target
temperature (55°F – 62°F). This is normal in all de-icers, but rest assured at
0°F to -10°F your de-icer will be operating properly. Completing our easy “Air
Test” will eliminate the concern that the thermostat is not turning off and is
heating up the water.
An “Air Test” determines whether the unit is heating properly and the
thermostat is turning on and off. To conduct the test, put the unplugged de-
icer into the freezer for 1 hour in order to “trick” the thermostat into turning
on. Remove the de-icer from the freezer and quickly plug the de-icer into a
known working outlet. The unit will begin to heat up then shut off within
seconds for Copper Heating Element units and within two (2) to three (3)
minutes for Cast Aluminum Heating Element units. After heating up to the off
position of the thermostat, you should hear a slight click. That sound is the
thermostat shutting the de-icer off. The unit works fine!
No – there is not a de-icer on the market with a moisture sensor to turn the
unit off when out of water. The copper heating element units will operate for
only a few seconds when out of water before turning off and the cast
aluminum heating element units for two (2) to three (3) minutes. But rest
assured they are totally safe and will not harm the unit or your application.
(Note: Caution should be exercised when removing models H-4810 and H-
4815 from the water as these do not have guards around the heating
element. We recommend always unplugging any unit before taking them out
of the water.)
This means that the manufacturer has tested the unit in plastic, structural
foam, and pond liners in the worst conditions to assure the unit will not harm
the application. All tests are conducted in accordance with Underwriters
Laboratories testing specifications.
The unit has passed very stringent testing procedures by UL ensuring
the unit is ultimately safe for consumer use. UL is a non-profit organization
dedicated to consumer safety around the world.
Measure length, width, and depth then follow this formula: L x W x D = Cubic
Feet x 7.47 = volume in gallons.
Watts divided by volts = amps. Example: 1500watt de-icer / 120VAC =
12.5amps
The type of de-icer used (floater, submergible, drain plug) is based upon
preference. However, depending upon the gallon requirements in your
application and the expected air temperatures, we recommend different
wattage requirements. See our table under “Specifications” on our webpage.
First, remove the entire drain plug assembly from the Rubbermaid Stock Tank
by unscrewing the 2” black nut on the outside of the stock tank. The drain
plug assembly will include the black flange housing with the 1.5” drain plug,
two (2) washers, and 2” black nut. Remove the Rubbermaid drain plug
assemble from the stock tank. Next, insert our DPH-15 Drain Plug De-icer
with one (1) orange washer on the threaded flange from the inside of the
tank through the 2” assemble hole. Finally, insert the last orange washer
onto the threaded flange from the outside of the tank then carefully tighten
our 2” threaded black nut onto the threaded flange. Do not over tighten!
The Model TC-3 (On at 35F, off at 45F) is the most common ThermoCube sold
because it is designed for winter use. The ThermoCubes operate by reading
the ambient temperature then turning the Cube on and off according to their
specific pre-set temperatures. It is not reading water temperature. Hence,
the use of a ThermoCube will help save in electricity and wear-n-tear on your
devices plugged into the Cube.
The ThermoCube, Model TC-3 will help save you electricity when the de-icer is
going to be used in applications containing more than 250 gallon. The de-
icer’s internal thermostat is set to turn the unit on when the water is slightly
above freezing then continue to operate until the water temperature in the
whole application has heated up to approximately 45F. In larger applications
(above 250 gallons) the thermostat will probably never turn the unit off, for
again, the unit is trying to heat the entire amount of water up to 45F. Why
use a ThermoCube – the Cube will turn the device plugged into the Cube on
and off according to the pre-set temperature reading the “air temperature”
not water temperature. So when
Other Farm Innovator Products

Rubbermaid Drain Plug De-Icer
Model DPH-15
Traditional Submergible De-Icer
Model H-429, H-439
3 Gallon Heated Flat-Back Bucket
Model FB-80
“Signature Series” Heated Pet Bowls
Model SB-40, SB-60
Floating Tank De-Icer
Model H-418
Cast Aluminum Bucket De-Icer
Model H-49
Baby Chick Starter Home
Model 3700
Cast Aluminum Utility Birdbath De-Icer
Model C-250